tng:settings:settings-program_options_probe_measure

Program Options - Probe & Measure

Probe 1 Pin

Assigns digital input pin of controller as Probe 1. Input pin is selected from drop down menu.

Probe 2 Pin

Assigns digital input pin of controller as Probe 2. Input pin is selected from drop down menu.


Related parameters

Probe Speed and Speed Low

Probe speed is speed at which machine measures different geometries under Machine/Measure menu.

Speed Low

After initial first probe activation, machine will repeat measurement again, but this time at Low speed.


Measure procedures are described here: Measure menu

Related parameters

Probe Size Z

Probe Size X and Y

Radius of the stylus ball of touching probe.

Off X

In a case where probe center is not aligned with Z axis center over X axis, user can set offset value.

Off Y

In a case where probe center is not aligned with Z axis center over X axis, user can set offset value.

Related parameters

Probe Travel

Probe Over Edge

Probe Length

This is the distance from the tip of the probe stylus ball to the edge of the probe shoulder. This value is considered when calculating distances in the measurement procedure so that the probe is not damaged.

Related parameters

Use Tool Table

TNG offers option where tool in tool table can be set as probe. When this option is enabled, probe properties(diameter, speed, length) are considered the one that are set in the tool table.

Related parameters

Safe Height

Height value to which machine ascends in-between the measurement procedure.

Related parameters

Return Distance

Height distance for which machine retracts after probe activation.

Related parameters

Probe EStop

During machine operation(machine jogging or NC program execution), if probe input is activated, Estop will be activated.

Related parameters